MIL-PRF-85045/17C
TABLE II. Qualification and conformance inspection Continued.
Cable length 1/
2/ 3/ 4/
Group
Qualification
Requirement
Test
Conformance
inspection
paragraph
paragraph
inspection
8/
2 samples, 0.5 km each 6/
III
Temperature cycling
3.7.1
C
(1 on reel, 1 off)
2 samples, 0.5 km each 9/
Temperature
3.7.3
4.7.6.3
C
humidity cycling
2 samples, 0.5 km each 9/
Storage temperature
3.7.4
4.7.6.4
--
2 specimens, 8 m each 10/
Low temperature
3.6.3
4.7.5.3
B
flexibility (cold bend)
6 specimens, 5 m each 11/
Cyclic flexing
3.6.4
4.7.5.4
--
(2 specimens at each temp)
2 specimens, 5 m each 10/
Crush
3.6.5
4.7.5.5
--
6 specimens, 5 m each 11/,
Cable twist-bend
3.6.6
4.7.5.6
C
(3 specimens at each temp)
2 specimens, 5 m each 9/
Impact
3.6.8
4.7.5.8
C
2 specimens, 300 m each 10/
8/
8/
Temperature life (life
C
aging)
2 specimens, 150 m each 12/
Tensile loading and
3.6.1
4.7.5.1
C
elongation
2 specimens, 150 m each 13/
Operating tensile
3.6.1.1
4.7.5.1.1
C
loading
2 specimens, 0.5 m each 10/
Fungus resistance
3.8.4
4.8.4
--
2 specimens, 0.5 m each 10/
Cable element
3.6.18
4.7.5.18
C
removability
1 specimen, 0.49 km each 6/
IV
Thermal shock
3.7.2
4.7.6.2
--
(on reel)
1 specimen, 2 m 14/ and 3
Weathering
3.7.8
4.7.6.8
--
material samples 15/
1 specimen, 2 m 14/ and 3
Fluid immersion
3.7.9
4.7.6.9
C
material samples 15/ for each
specified fluid
2 specimens, 2 m 16/
Paint susceptibility
3.7.15
4.7.6.15
--
1 specimen, 30 m 14/
Jacket self-adhesion
3.7.11
4.7.6.11
--
or blocking
1 specimen, 30 m 14/
Shock
3.7.13
4.7.6.13
--
1 specimen, 150 m 17/
Dynamic bend
3.6.2
4.7.5.2
B
1 specimen, 1.5 m 13/
Hosing: low pressure
3.6.12.1
4.7.5.12.1
C
1 specimen, 2 m 13/
Hosing: hydrostatic
3.6.12.2
4.7.5.12.2
C
1 specimen, 10 m 13/
Radial compression
3.6.7
4.7.5.7
--
(for application B
only)
2 specimens, 5 m 16/
Corner bend
3.6.9
4.7.5.9
--
8/
8/
2 specimens, 1 m 16/
OFCC kink
--
5
For Parts Inquires call Parts Hangar, Inc (727) 493-0744