MIL-PRF-85045/18C
TABLE II. Qualification and conformance inspection Continued.
Qualification
Requirement
Test
Conformance
Cable length 1/
2/
Group
inspection
paragraph
paragraph
inspection
5/
2 samples, 0.5 km each 4/
III
Temperature
3.7.1
C
cycling
(1 on reel, 1 off)
2 samples, 0.5 km each 6/
Temperature
3.7.3
4.7.6.3
C
humidity cycling
2 samples, 0.5 km each 6/
Storage
3.7.4
4.7.6.4
--
temperature
2 specimens, 8 m each 7/
Low temperature
3.6.3
4.7.5.3
B
flexibility (cold
bend)
6 specimens, 5 m each 8/
Cyclic flexing
3.6.4
4.7.5.4
--
(2 specimens at each temp)
2 specimens, 5 m each 7/
Crush
3.6.5
4.7.5.5
--
6 specimens, 5 m each 8/
Cable twist-bend
3.6.6
4.7.5.6
C
(3 specimens at each temp)
2 specimens, 5 m each 6/
Impact
3.6.8
4.7.5.8
C
2 specimens, 300 m each 7/
5/
5/
Temperature life
C
(life aging)
2 specimens, 150 m each 9/
Tensile loading
3.6.1
4.7.5.1
C
and elongation
2 specimens, 150 m each 10/
Operating tensile
3.6.1.1
4.7.5.1.1
C
loading
2 specimens, 0.5 m each 7/
Fungus resistance
3.8.4
4.8.4
--
2 specimens, 0.5 m each 7/
Cable element
3.6.18
4.7.5.18
C
removability
1 specimen, 0.49 km each 4/ (on
IV
Thermal shock
3.7.2
4.7.6.2
--
reel)
1 specimen, 2 m 11/ and 3 material
Weathering
3.7.8
4.7.6.8
--
samples 12/
1 specimen, 2 m 11/ and 3 material
Fluid immersion
3.7.9
4.7.6.9
C
samples 12/ for each specified
fluid
2 specimens, 2 m 13/
Paint
3.7.15
4.7.6.15
--
susceptibility
1 specimen, 30 m 11/
Jacket self-
3.7.11
4.7.6.11
--
adhesion or
blocking
1 specimen, 30 m 11/
Shock
3.7.13
4.7.6.13
--
1 specimen, 150 m 14/
Dynamic bend
3.6.2
4.7.5.2
B
1 specimen, 1.5 m 11/
Hosing: low
3.6.12.1
4.7.5.12.1
C
pressure
1 specimen, 2 m 11/
Hosing:
3.6.12.2
4.7.5.12.2
C
hydrostatic