MIL-PRF-85045/18C
TABLE II. Qualification and conformance inspection Continued.
Qualification
Requirement
Test
Conformance
Cable length 1/
2/
Group
inspection
paragraph
paragraph
inspection
1 specimen, 10 m 11/
Radial
3.6.7
4.7.5.7
--
compression (for
application B
only)
2 specimens, 5 m 13/
Corner bend
3.6.9
4.7.5.9
--
2 specimens, 1 m 13/
5/
5/
OFCC kink
--
2 specimens, 1 m 13/
5/
5/
Cross-link
C
verification
1 specimen, 30 cm 11/
V
Dripping
3.6.13
4.7.5.13
--
Cable jacket tear
3.6.14
4.7.5.14
5 flat extruded jacket material
C
strips 15/
strength
5 specimens 16/
Cable jacket
3.6.15
4.7.5.15
--
material tensile
strength and
elongation
4 specimens, 2 m 17/
Cable abrasion
3.6.16
4.7.5.16
C
resistance
3 specimens, 0.5 m 13/
Cable shrinkage
3.6.17
4.7.5.17
C
3 specimens, 2 m each 13/
Durability of
3.6.19
4.7.5.19
--
identification
1 specimen, 50 m 11/
Flame
3.7.12.2
4.7.6.12.2
C
extinguishing and
smoke generation
Water absorption
3.7.14
4.7.6.14
2 specimens, extruded jacket
--
material strips 16/
1 specimen, 1 m 18/
VI
Acid gas
3.8.1
4.8.1
C
generation
1 specimen, 1 m 18/
Halogen content
3.8.2
4.8.2
--
1 specimen, 1 m 18/
Toxicity index
3.8.3
4.8.3
C
1 specimen, 1 m 18/
Smoke index
3.8.5
4.8.6
C
6