MIL-PRF-85045/15B
Temperature cycling: Change in optical transmittance measurements may be made
periodically. At a minimum, one optical transmittance measurement shall be made
over a period of 1 hour at the end of each temperature plateau.
Temperature humidity cycling: Change in optical transmittance measurements may
be made periodically. At a minimum, one optical transmittance measurement shall
be made at the end of each temperature plateau.
Storage temperature:
Applicable.
Weathering:
Applicable.
Fluid immersion: Exposure to automobile gasoline and tap water are not required
and the test temperature for lubricating oil exposure shall be 73 C to 77 C. The
tensile strength retention of the cable jacket material after exposure to
hydraulic fluid shall be not less than 30 percent.
Flame extinguishing:
Applicable.
Smoke generation and flame propagation: Applicable, except the pass/fail
criteria shall be as follows. The peak optical density and the average optical
density of smoke produced shall be not greater than 0.5 and 0.15 respectively.
In addition, the flame spread-time product at the 10 minute point shall be not
greater than 27.5 meters-minutes when calculated in accordance with ASTM-E-84.
Shock:
Applicable.
Paint susceptibility:
Applicable.
Electromagnetic effects:
Applicable.
Chemical properties:
Halogen content:
< 0.2 percent.
Part or Identifying Number (PIN) (see table I):
M85045/15-01P (Multimode).
M85045/15-02P (Single-mode).
"P" designates 7.7 Mpa hydrostatic pressure proof cable.
TABLE I.
Supersession data.
PIN
Superseding
M85045/15-01
M85045/15-01P
M85045/15-01N
M85045/15-01T
M85045/15-02
M85045/15-02P
M85045/15-02N
M85045/15-02T