MIL-PRF-85045/15B
Qualification by similarity:
Manufacturers who produce products for MIL-PRF-85045/13 and products for this
specification sheet, and are qualified under MIL-PRF-85045/13 and pass the
attenuation rate, low temperature flexibility (cold bend), impact, low pressure
hosing, abrasion, smoke generation and flame propagation, flame extinguishing, and
size inspection specified herein, are qualified under this specification sheet.
Testing may be performed on a single length of cable, with a minimum length of 0.5
km.
Manufacturers who produce products for MIL-PRF-85045/18 and products for this
specification sheet and are qualified under MIL-PRF-85045/18 and pass the
attenuation rate, low temperature flexibility (cold bend), impact (low temperature
only), low pressure hosing, cable abrasion resistance, smoke generation and flame
propagation, flame extinguishing, cable jacket material tensile strength and
elongation, durability of identification, size, cable life (both jacket material
and complete cable), cyclic flexing, electromagnetic effects, dripping, weathering,
fluid immersion, paint susceptibility, acid gas generation, halogen content,
toxicity index, and fungus inspections specified herein, are qualified under this
specification sheet. This qualification by similarity is applicable if the only
difference between the previously qualified MIL-PRF-85045/18 cable and this MIL-
PRF-85045/15 cable is the outer jacket material. If the MIL-PRF-85045/15 cable is
identical to the previously qualified MIL-PRF-85045/18 cable, no testing is
required for qualification. A certificate of compliance may be submitted in lieu
of performing the acid generation, halogen content, toxicity index and fungus
inspections. Testing may be performed on a single length of cable, with a minimum
length of 0.5 km.
Manufacturers who are qualified under this specification sheet for multimode fiber
cable and whose single-mode fiber cable passes the visual and mechanical,
attenuation rate, temperature cycling, humidity, storage temperature, cyclic
flexing, crush, cable twist-bending, impact (low temperature only), tensile loading
and elongation, operating tensile loading, thermal shock and dynamic bend
inspections specified herein, are qualified under this specification sheet for
single mode fiber cable. This qualification by similarity is applicable if the
only difference between the previously qualified cable and the cable under test is
that the optical fiber has been changed from a multimode fiber to a single-mode
fiber. Testing may be performed on either one or two lengths of cable, each with a
minimum length of 0.5 km. Test order must be observed up to and including the
storage temperature test. If only one cable length is used the thermal shock test
shall be performed after the storage temperature test. Manufacturers who are
qualified under MIL-PRF-85045/13 for both multimode and single mode fiber cable and
under this specification sheet for multimode fiber cable are qualified under this
specification sheet for single mode fiber cable.
Manufacturers who are qualified under MIL-PRF-85045/13 for both multimode and
single-mode fiber cable and under this specification sheet for multimode fiber
cable are qualified under this specification sheet for single-mode fiber cable.
Custodians:
Preparing activity:
Army - CR
Navy - SH
Navy - SH
Air Force - 11
Agent:
NASA - NA
DLA - CC
Review activities:
(Project 6015-0034-03)
Army - AR, AV, MI
Navy - EC, YD
Air Force - 02, 19, 80, 99
DLA - CC
5