MIL-PRF-85045/19A
Mass per unit length:
< 15 kg/km.
Short term minimum bend diameter:
Eight times the OFCC outer diameter.
Long term minimum bend diameter:
Sixteen times the OFCC outer diameter.
> 270 N.
Tensile loading:
Dynamic bend tensile load: 90 N minimum.
Jacket material: The OFCC jacket shall be composed of a low halogen, low smoke,
low toxicity polymer material.
OFCC color:
Slate (MIL-PRF-49291/6 fiber).
Yellow (MIL-PRF-49291/7 fiber).
OFCC marking: Each OFCC shall be uniquely marked with a number between 1 and 36.
The form of the marking shall be the printed spelling of the number, followed by
a dash, followed by the printed arabic numeral. The marking shall be applied and
repeated every 0.10 m (4 inches) along the OFCC jacket. OFCC number 1 shall be
located in the innermost ring of OFCCs. OFCCs shall be consecutively numbered
starting with those in the inner most ring (1 through 6), then those in the
middle ring (7 through 18) and finally those in the outer most ring (19 through
36). OFCC's numbered 1, 7 and 19 shall be located along approximately the same
radial line within the cable.
Finished cable:
Dimensions and configuration: See figure 2. Twenty-four to thirty-six OFCC
units shall be helically layered over the central member. The minimum outer
jacket thickness shall be not less than 1.9 mm (establishes compatibility with
termination and penetration devices).
Number of fibers:
24, 33, or 36 (one per OFCC).
Note 1.
OFCC - Optical fiber cable component
FIGURE 2.
Twenty-four, thirty-three, and thirty-six OFCC fiber optic cable.