MIL-PRF-85045/16C
TABLE I. Qualification and conformance inspection.
Qualification
Requirement
Test
Conformance
Cable length 1/
2/ 3/ 4/
Group
inspection
paragraph
paragraph
inspection
3 samples, 0.5 km each 5/
I
Visual and
3.4, 3.9, 3.10
4.7.2
A
mechanical
inspection
3 samples, 0.5 km each 6/
Attenuation rate
3.5.1
4.7.4.1
A
7/
2 samples, 0.5 km each 6/
III
Temperature cycling
3.7.1
C
(1 on reel, 1 off)
2 samples, 0.5 km each 8/
Temperature
3.7.3
4.7.6.3
C
humidity cycling
2 specimens, 8 m each 9/
Low temperature
3.6.3
4.7.5.3
B
flexibility (cold
bend)
6 specimens, 5 m each 10/
Cyclic flexing
3.6.4
4.7.5.4
--
(2 specimens at each temp)
2 specimens, 5 m each 9/
Crush
3.6.5
4.7.5.5
--
2 specimens, 300 m each 9/
7/
7/
Temperature life
C
(life aging)
2 specimens, 150 m each 11/
Tensile loading and
3.6.1
4.7.5.1
C
elongation
2 specimens, 150 m each 12/
Operating tensile
3.6.1.1
4.7.5.1.1
C
loading
2 specimens, 0.5 m each 9/
Fungus resistance
3.8.4
4.8.4
--
2 specimens, 0.5 m each 9/
Cable element
3.6.18
4.7.5.18
C
removability
2 specimens, 6 m each 9/
Flammability
3.7.12.1
4.7.6.12.1
C
(60-degree angle)
1 specimen, 0.49 km each 6/ (on
IV
Thermal shock
3.7.2
4.7.6.2
--
reel)
1 specimen, 30 m 13/
Jacket self-adhesion
3.7.11
4.7.6.11
--
or blocking
1 specimen, 150 m 14/
Dynamic bend
3.6.2
4.7.5.2
B
2 specimens, 5 m 15/
Corner bend
3.6.9
4.7.5.9
--
2 specimens, 1 m 15/
7/
7/
OFCC kink
--
V
Cable jacket tear
3.6.14
4.7.5.14
5 flat extruded jacket material
C
strips 16/
strength
5 specimens 17/
Cable jacket
3.6.15
4.7.5.15
--
material tensile
strength and
elongation
7/
7/
1 specimen 18/
Flaming smoke
C
generation
4
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.